Walk-in and commercial freezer repair
Freezers usually fail slowly: a little more ice, a degree or two warmer each day, then product starts to soften. Call any time and we connect you with an independent, licensed refrigeration contractor near you.
Freezer warming?Answered 24/7(555) 010-0188What a healthy freezer looks like
Most kitchens hold walk-in freezers at 0°F or below. The coil carries a light frost between defrost cycles, the floor stays dry, and the door closes and seals on its own. Anything else is a warning sign.
The most common freezer problems
| What you notice | Usual cause |
|---|---|
| Coil buried in ice, little air moving | Defrost timer, heater or termination thermostat failed |
| Ice building on the floor or ceiling near the door | Door not sealing, failed door heater wire, door left open |
| Water or ice under the evaporator | Drain line frozen or drain heater failed |
| Temperature creeping up over days | Dirty condenser, refrigerant leak, iced coil |
| Door hard to open, then won't close | Pressure relief port iced, gasket or hinge problem |
| Grinding or rattling inside | Fan blade hitting ice, or a failing fan motor |
Safe checks before you call
- Check the door gasket all the way around, especially the bottom corners, for tears and gaps.
- Make sure the door closes on its own and the strip curtain is in place.
- Look at where the ice is: on the coil, on the fans, on the floor, or around the door. Tell the tech.
- Don't chip or pry ice off the coil. It's easy to puncture a tube and turn a defrost repair into a leak repair.
- Leave electrical and refrigerant work to a certified technician.
When to move product
If the freezer is still at or near 0°F, product is usually fine while you wait for service; keep the door closed. If it's well above 0°F and climbing, move what you can to a working freezer and keep a record of temperatures and times. Thawed food that needs temperature control falls under the same 41°F cold-holding rule as your cooler, so ask your inspector before you refreeze or serve it.
Typical costs
| Job | Typical range |
|---|---|
| Service call and diagnosis | About $120–$150 in business hours |
| Defrost parts, drain heater, fan motor, gasket | Usually the lower part of $180–$1,600 |
| Refrigerant leak repair and recharge | Depends on the leak and the pounds of refrigerant needed |
Ranges from contractor listings and published cost guides. Your contractor prices the actual job.
Commercial reach-in and chest freezers
The same causes apply to reach-in and chest freezers: dirty condenser coils, door gaskets, defrost failures and fans. See reach-ins and prep tables.
Calls answered 24/7
Still stuck?
Tampa Bay Refrigeration is a referral service, not a contractor. We may be paid by the contractor for the referral.